Fault 29 HW limit switches

Subfault: 29.1

Description: Positive limit switch hit

 

Response: HW limit switch – current drive train

Cause

Measure

Positive hardware limit switch hit.

– Check the wiring of the hardware limit switch.

– Check the target position.

– Move clear of the hardware limit switch at negative speed.

Subfault: 29.2

Description: Negative limit switch hit

 

Response: HW limit switch – current drive train

Cause

Measure

Negative hardware limit switch hit.

– Check the wiring of the hardware limit switch.

– Check the target position.

– Move clear of the hardware limit switch at positive speed.

Subfault: 29.3

Description: Limit switch missing

 

Response: Emergency stop + output stage inhibit

Cause

Measure

Both positive and negative hardware limit switches hit at the same time.

– Check the wiring of the hardware limit switches.

– Check the parameter setting of the digital inputs.

– Check the parameter setting of the process output data.

Subfault: 29.4

Description: Limit switches swapped

 

Response: Emergency stop + output stage inhibit

Cause

Measure

Positive hardware limit switch hit at negative speed, or negative hardware limit switch hit at positive speed.

Check whether hardware limit switch connections are swapped.