Fault 44 Subcomponent power section
Subfault: 44.2 Description: Overcurrent phase U | ||
---|---|---|
| Response: Remote – critical fault | |
Cause | Measure | |
Overcurrent phase U. | – Rectify the short circuit. – Connect a smaller motor. – Increase the ramp time. – If the output stage is defective, contact SEW‑EURODRIVE Service. |
Subfault: 44.3 Description: Overcurrent phase V | ||
---|---|---|
| Response: Remote – critical fault | |
Cause | Measure | |
Overcurrent phase V. | – Rectify the short circuit. – Connect a smaller motor. – Increase the ramp time. – If the output stage is defective, contact SEW‑EURODRIVE Service. |
Subfault: 44.4 Description: Overcurrent phase W | ||
---|---|---|
| Response: Remote – critical fault | |
Cause | Measure | |
Overcurrent phase W. | – Rectify the short circuit. – Connect a smaller motor. – Increase the ramp time. – If the output stage is defective, contact SEW‑EURODRIVE Service. |