Fault 11 Temperature monitoring

Subfault: 11.1

Description: Heat sink overtemperature

 

Response: Output stage inhibit

Cause

Measure

Air circulation has been disrupted. Maximum permitted heat sink temperature exceeded.

– Check air circulation.

– Ensure sufficient cooling.

Fan defective. Maximum permitted heat sink temperature exceeded.

Contact SEW‑EURODRIVE Service.

The temperature sensor is defective. Maximum permitted heat sink temperature exceeded.

Contact SEW‑EURODRIVE Service.

The capacity utilization is too high. Maximum permitted heat sink temperature exceeded.

– Reduce the load.

– Reduce the PWM frequency.

– Reduce the ambient temperature.

Subfault: 11.7

Description: Wire break at temperature sensor of heat sink

 

Response: Output stage inhibit

Cause

Measure

Wire break at temperature sensor of heat sink.

Contact SEW‑EURODRIVE Service.

Subfault: 11.8

Description: Short circuit at temperature sensor of heat sink

 

Response: Output stage inhibit

Cause

Measure

A short circuit was detected at the temperature sensor of the heat sink.

Contact SEW‑EURODRIVE Service.