P6-18 DC braking voltage level
Setting range: Auto, 0.0 – 30.0%
This parameter activates the DC braking function in relation to the rated motor voltage (P1-07).
The motor is decelerated with the deceleration ramp (P1-04) and the braking energy is thereby fed back into the motor winding.
An excessive value will cause the motor to jerk.