P6-04 Hysteresis band user relay/analog outputs
Setting range: 0.0 – 0.3 – 25.0%
This parameter functions together with the function selection 2 (motor at setpoint speed) or 3 (motor speed > 0) in parameter P2-11 (DO1), P2-13 (DO2), P2-15 (relay 1) and P2-18 (relay 2).
If the speed lies within the set hysteresis band (+/- P6-04 of P1-01), depending on the function selection, the respective digital output or the corresponding relay is active (1).
If the value is too small, the digital output or relay “bounces”.
[1] | Depending on the setting in P2-11, P2-13, P2-15, P2-18 |
[2] | Percentage hysteresis of P6-04 referred to P1-01 |