P6-08 Max. frequency for speed setpoint

Setting range: 0; 5 – 20 kHz

This parameter defines the frequency of the frequency input (DI3) at which the motor speed setpoint corresponds to the maximum speed (P1-01).

An individual configuration of the digital inputs with P1-15 = 0 and parameter group 9 is necessary to be able to use this function.

Select the option "Pulse" at one of the corresponding speed sources (P9-10P9-17).

When set to 0, this function is deactivated.