Fixed setpoints – deceleration 1, 2

This menu item allows you to specify the fixed setpoints for the deceleration of drive trains 1 and 2.

INFORMATION

In the factory setting, only the application limits are effective. For the fixed setpoints to take effect, you must change the parameter Maximum deceleration – source (index 8377.31) to the value 2020A2 hex (fixed setpoints acceleration). For information on changing the parameter, refer to chapter Access to parameters via index.
The values can be specified with a maximum of 8 integer places and 2 decimal places in the system unit min-1.

7-segment display

Parameters

Index

Application limit – deceleration DT1

8357.13

Fixed setpoint – deceleration 1 DT1

8354.50

Fixed setpoint – deceleration 2 DT1

8354.52

Application limit – deceleration DT2

8358.13

Fixed setpoint – deceleration 1 DT2

8354.51

Fixed setpoint – deceleration 2 DT2

8354.53

"Set fixed setpoints deceleration" sequence