Closed loop

Closed loop | Speed profile

0x8280-01 – Setpoint operating mode

Operating mode: 1: Speed profile

0x8F00-01 – Encoder feedback configuration

3: Closed loop (FOC)

Closed loop – Field-oriented control (FOC)

0x8400-03 – Position profile target speed

Specification of the target speed

0x8480-02 – Actual position

Encoder value normalized to position

0x8F00-02 – Encoder – Actual value

Encoder value

Closed loop has the following features:

  • The function module operates with closed-loop control using a cascaded controller structure.
  • The encoder signal is not taken into account by the controller.
  • The setpoint for the current controller is generated by the higher-level closed loop system.
  • An encoder value is output. See chapter Closed loop – Field-oriented control (FOC) for more information.

Start

Start parameter

Limit Velocity

Speed limitation

Limit Current

Current limitation

Limit Voltage

Voltage limiting

Vel

Speed profile

PI control

PI current controller

int. PS

Internal power stage

M

Motor

Encoder

Actual encoder value

Start – Speed profile parameters

INFORMATION

Please read the following chapters:
Startup preparations
Application data
Vel – Speed profile

Start

 

Vel

 

 

Vel control

Speed control

 

Limit – speed limitation
Vel control – speed controller
Limit Current

0x8C00-04 – Motor parameters – Maximum current

 

Limit

Current

 

 

Current

control

Current controller

 

0x8600-04 – Current limit

Current control
Limit Voltage
Internal PS – power output stage, motor, encoder

Limit

Voltage

Voltage limiting

 

int. PS

 

 

Motor

Encoder

0x8F00-02 – Encoder – Actual value

 

0x8680-02 – Power supply – Voltage actual value

Current

control

Current controller

0x8600-02 – Current – Actual value