Use according to category 3, PL d

WARNING

Extended braking distance of the configured drive system when using the incorrect brake application time.
Severe or fatal injuries.
  • When using the brake module according to category 3, PL d, you must use one of the following brake application times:
  • Brake application time t2,I for 3-wire brakes with cut-off in the AC circuit
  • Brake application time according to brake documentation for 2-wire brakes

Characteristic values according to EN ISO 13849‑1

Classification

PL d

System structure

Category 3

Probability of dangerous failure per hour (PFHD value)

0 (fault exclusion)

Mission time/service life

20 years

Safe state

The electrical power supply to the brake is interrupted.

Safety sub-function

Safe disconnection of the power supply to the brake