Error 46 Safety option

Subfault: 46.1

Description: No response from safety option

 

Response: Output stage inhibit

Cause

Measure

No synchronization could be performed with the safety option.

– On the connectible safety card, check the device assignment of the basic device and the safety card.

– On the connectible safety card, check the slot and installation of the safety card.

– Switch the device off and on again.

– If the fault occurs repeatedly, contact SEW‑EURODRIVE Service.

Subfault: 46.2

Description: Invalid variant

 

Response: Output stage inhibit

Cause

Measure

Safety option variant does not match inverter type.

Use the correct safety option variant.

In the double axis of a MOVIDRIVE® modular application inverter, only safety cards without encoder interface are allowed to be used.

Use the correct safety card variant.

Subfault: 46.3

Description: Internal communication timeout

 

Response: Output stage inhibit

Cause

Measure

Communication between inverter and safety option interrupted.

– Check the installation in the connectible safety card.

– If the fault occurs repeatedly, contact SEW‑EURODRIVE Service.

The safety option signaled a warning.

– Check the installation in the connectible safety card.

– If the fault occurs repeatedly, contact SEW‑EURODRIVE Service.

Subfault: 46.50

Description: Warning

 

Response: Warning with self-reset

Cause

Measure

Safety option signaled a warning

Observe the warning of the safety option subcomponent. Obtain the exact cause from this warning and take the appropriate remedy measures.

Subfault: 46.51

Description: Faults

 

Response: Emergency stop + output stage inhibit with self-reset

Cause

Measure

Safety option detected an error.

Observe the error code of the safety option subcomponent. Obtain the exact cause of the error from this error message and take the appropriate fault elimination measures.

Subfault: 46.52

Description: System error/critical error

 

Response: Output stage inhibit with self-reset

Cause

Measure

Safety option detected system error or critical error.

Observe the error code of the safety option subcomponent. Obtain the exact cause of the error from this error message and take the appropriate fault elimination measures.