Fault 35 Function activation

Subfault: 35.1

Description: Activation level – invalid activation key

 

Response: Emergency stop + output stage inhibit

Cause

Measure

Activation key not entered properly.

Enter the activation key again.

The activation key was not created for this device.

Check the activation key.

In a double axis, the activation key of the wrong instance was entered in the device.

Enter the activation key for the assigned instance.

Activation key entered for technology level in parameter "Application level – activation key".

Enter the activation key in the correct parameter.

Subfault: 35.2

Description: Application level too low

 

Response: Emergency stop + output stage inhibit

Cause

Measure

The activated software module requires a higher application level.

Determine the required application level ("Application level – required level" parameter) and enter its activation key.

Subfault: 35.3

Description: Technology level too low

 

Response: Emergency stop + output stage inhibit

Cause

Measure

An activated technology function requires a higher technology level.

Determine the required technology level ("Technology level – required level" parameter) and enter its activation key.

Subfault: 35.4

Description: Technology level – invalid activation key

 

Response: Emergency stop + output stage inhibit

Cause

Measure

Activation key not entered properly.

Enter the activation key again.

Activation key not created for this device.

Check the activation key.

In a double axis, the activation key of the wrong instance was entered in the device.

Enter the activation key for the assigned instance.

Activation key entered for application level in parameter "Technology level – activation key".

Enter the activation key in the correct parameter.