Status display

Error/status

Symbol

State

Meaning

Connection error

No connection to the inverter.

Error

The inverter signals a device fault.

Warning

The inverter signals a device warning.

Emergency mode active

The MOVISAFE® CS.. A emergency mode is active.

State of the output stage and device status

The current device status of the inverter is displayed next to the symbol for the output stage state. If a device fault is present, the fault number is displayed instead.

Symbol

State

Meaning

Not ready

The inverter is in "Not ready" state.

Ready, output stage not enabled

The inverter is in "Ready" status. The output stage is not enabled.

Ready, output stage enabled

The inverter is in "Ready" status. The output stage is enabled.

Examples of the device status:

  • "02" means "Function Control Block (FCB) 02 Stop standard".
  • "C2" means "STO active".

For detailed information on the current device status, refer to the menu Diagnostics > Device status.

Example of a device fault:

  • "11.21" means "Heat sink overtemperature error".