Load cycling
Load cycling can be used to move back and forth between two absolute positions.
[1] | Position of the software limit switches/application limits |
[2] | Actual position |
[3] | Setpoint positions 1 and 2 |
[4] | Symbols for selecting setpoints |
[5] | Setpoint input |
- In the Manual mode menu, select the Load cycling icon.
- Confirm with the <OK> key.
- Set the following setpoints [3]. Changes to the values have a direct effect on the drive.
Symbol | Description |
|---|---|
| Specify the setpoint position 1 of the pendulum movement in user units, e.g. rev. |
| Specify the setpoint position 2 of the pendulum movement in user units, e.g. rev. |
| Enter the desired setpoint speed in user units, e.g. rev/min. |
| Enter the desired setpoint acceleration/setpoint deceleration in user units, e.g. rev./(min*s). |
- To start load cycling, press the green <RUN> key.
- To stop load cycling, press the red <STOP> key.
- To stop manual mode, press the <Esc> key.
- The following query is displayed: Do you want to stop manual mode? Warning! An applied setpoint will be active again after stopping manual mode.
- Before stopping manual mode, check that there are no persons in the area of rotating parts.
- Confirm with the <OK> key.
- Manual mode has been stopped and pending setpoints become active again.