Data management

This menu item allows you to upload (store) or download (recall) the parameter set of an inverter. After downloading a parameter set, the drive can start running with pending control signals for setpoints.

"Data management" sequence
Messages

Data transfer from keypad to inverter failed. Press the OK key to acknowledge the message.

No valid data set is stored on the keypad. Press the OK key to acknowledge the message.

No download can be performed because the transferred data set originates from an inverter from another download group. The value of index 8301.9, byte 3 of the data set differs from the value of index 8300.9, byte 3 of the inverter. Press the ESC key to acknowledge the message.

At least one of the following discrepancies was detected:

  • The device family of the offered parameter set does not exactly match the own device family.
  • The device power of the offered parameter set deviates from the device's own power by more than a factor of 3.
  • The device voltage of the offered parameter set does not exactly match the own device voltage.

To cancel the download, press the ESC key. Press the OK key to execute the download.

When comparing the subcomponents, an option required in the data set was not found for the inverter. Index array 8301.40 of the data set differs from index array 8300.40 of the inverter.

To cancel the download, press the ESC key. Press the OK key to execute the download.

Safety prompt before a data set is transferred from the keypad to the inverter.