Status
If the SDI safety sub-function is activated and no movement is detected in the monitored direction of rotation, the status of the SDI function is active. The status of the SDI function is deactivated if movement in the monitored direction of rotation over the parameterized tolerance is detected.
The status of the SDI safety sub-function is displayed in the following areas:
- Diagnostics > MOVISAFE® CS..A, position function status
- Safe process input data (SDI1, SDI2)