Reference signals
INFORMATION
Only relevant with activated field bus connection.
Parameter group | Description |
---|---|
Comparison of setpoint/actual speed values | |
Half window width | Speed setpoint window |
Index: 8324.3 | |
IEC name: - | |
In position | |
Window width | If the difference between actual and setpoint positions is smaller than half this value, the "in position" signal is set. |
Index: 50031.1 | |
IEC name: - | |
Hysteresis | Target position hysteresis. When the position window is left, the "In position" signal is maintained until this value is exceeded. |
Index: 50031.2 | |
IEC name: - | |
Delay time | The condition for the "In position" signal must be fulfilled at least for this time. |
Index: 50031.3 | |
IEC name: - |