Proceed as follows:
- Select Drive train optimization > Load moment of inertia > Measuring in speed mode in the menu.
- The following query is displayed: "Do you want to start manual mode?"
- Confirm the query with the <OK> key.
- Manual mode is started. Manual mode can only be ended by exiting the moment of inertia menu.
- To change the settings for the Manual mode, press the second function key.
- In manual mode, Speed-controlled manual mode is activated. Specify the setpoints.
- To return to the Moment of inertia window, press the second function key again.
- To start the measurement, press the <OK> button.
- The measurement is performed.
- To stop the measurement, press the <OK> key.
- The measurement is stopped.
- To stop manual mode, press the <Esc> key.
- The following query is displayed: Do you want to stop manual mode? Warning! An applied setpoint will be active again after stopping manual mode.
- Before stopping manual mode, check that there are no persons in the area of rotating parts.
- Confirm with the <OK> key.
- Manual mode has been stopped and pending setpoints become active again.
- To exit the menu, press the <Esc> key.
- You have optimized the drive train.