Setting a main menu item as the start view
You can set which main menu item the keypad displays as soon as you switch on the inverter with the keypad connected or connect the keypad when the inverter is switched on. The following main menu items are possible:
- Inverter status, FCB number, fault number
- "Actual speed in min-1"
- Actual current in A
- DC link voltage in V
Proceed as follows to set a main menu item:
- Select the main menu item using the navigation keys.
- Press and hold the OK key for 2 seconds.
- The 7-segment display and the corresponding pictogram flash by way of confirmation.