Assigning the TUNID via MOVISUITE® Assist CS..

To assign the TUNID, the SNN must be read from the engineering tool of the fail-safe controller and added to MOVISUITE® Assist CS.. Furthermore, the target network ID (the device's IP address) must match the IP address of the EtherNet/IP™ interface connection and the configuration on the engineering tool of the fail-safe controller. To that end, the IP address of the EtherNet/IP™ interface connection must be read in MOVISUITE® and added to MOVISUITE® Assist CS..

The following requirements must all be fulfilled for this purpose:

  • In Assist CS.., the CIP Safety™ protocol type must be selected in the F-communication menu, and the Address assignment mode parameter must be set to "Via parameterization".
  • The inverter is already integrated in the EtherNet/IP™ network in the engineering tool of the fail-safe controller.
  • The IP address and the SNN of the inverter are configured in the engineering tool of the fail-safe controller.
  • The inverter is configured with the IP address.