Triggering and measuring

After triggering a touchprobe event, the positions are read, transformed, and projected onto the path. The determined Cartesian actual position is projected perpendicular to the MeasuringDirection onto the path of the robot. When using the "MEASURE" instruction, the projection point is output in the pose variable set there.

If the path segment into which is to be projected has no motion component in MeasuringDirection, an error is output. This is the case for example, if the MeasuringDirection is set to "z" but the robot moves along a straight line in x-y direction. If projection onto the current path segment is not spatially possible, an attempt is made to project the point onto one of the adjacent segments.

Path point

Description

P1 .. P4

Path points along the course of the path

Reg TP Event

Instruction for activating the touchprobe

TP event

Triggering the sensor or switching the BOOLEAN variable

PTP,Increments

Actual position or touchprobe position of the inverters

Pmeasured

Measuring point projected onto the path

In the figures, the touchprobe is shown vertically in z-direction in "Single" mode with MeasuringDirection. The green area represents the segments in which the touchprobe function is activated. After triggering of the triggers, the measured point (PTP,Increments) is projected onto the path (Pmeasured). The movement of the robot itself is not affected.

 

Path point

Description

P1 .. P3

Path points along the course of the path

Reg TP Event

Instruction for activating the touchprobe

Dereg TP Event

Instruction for deactivating the touchprobe

TP event

Triggering the sensor or switching the BOOLEAN variable

PTP,Increments

Actual position or touchprobe position of the inverters

Pmeasured

Measuring point projected onto the path

 

In "Multiple" mode, the touchprobe function remains active after a trigger is triggered (MeasuringDirection is in z-direction). If another trigger is triggered, the newly measured point is also projected onto the path, and Pmeasured is overwritten. The event is active (green area) until a "DEREG Touchprobe_EVENT" instruction is interpreted, the program ends or is stopped.

Path point

Description

P1 .. P3

Path points along the course of the path

Reg TP Event

Instruction for activating the touchprobe

TP event

Triggering the sensor or switching the BOOLEAN variable

PTP,Increments

Actual position or touchprobe position of the inverters

Pmeasured

Measuring point projected on path

If the touchprobe sensor is triggered within a blending curve, the point is projected onto the path that was interpolated without blending (figure: MeasuringDirection z-direction, "Single" mode).