Inverter settings

[1]

Start load moment of inertia measurement

[2]

Currently measured load inertia in kg*cm2

[3]

Measured mean value of load inertia in kg*cm2

[4]

Deviation of currently measured mean value from previous measured value in %

[5]

Transmit the mean value of the load inertia to all inverters

[6]

Selection of whether the load inertia is to be transmitted in a voltage-fail-safe manner (only visible in "Expert mode")

[7]

Currently set (active) load inertia in kg*cm2

[8]

Stiffness (entered via edit box or slider)
INFORMATION: A change to this value is automatically transferred to all the inverters

[9]

Zero clearance (entered via edit box or slider)
INFORMATION: A change to this value is automatically transferred to all the inverters

[10]

Suggested values determined on the basis of clearance and stiffness
(only visible in "Expert mode")

[11]

Apply suggested values
Requirement: "Advanced settings" [15] active
(only visible in "Expert mode")

[12]

Current effective setting values
Requirement for manual adjustment: "Advanced settings" [15] active
(only visible in "Expert mode")

[13]

Transfer setting values of the control to all inverters

[14]

Selection of whether the control setting values are to be transmitted in a voltage-fail-safe manner (only visible in "Expert mode")

[15]

"Advanced settings" for inhibiting the input of the stiffness/zero backlash and for enabling the manual adjustment of controller values independently of each other (only visible in "Expert mode").