P3-09 PID correcting variable limitation
- 0: Fixed setpoint limit/PID output range limited by P3-07 and P3-08.
- 1: Analog input 1 variable upper limit/PID maximum output limited by the signal present at analog input 1.
- 2: Analog input 1 variable lower limit/PID minimum output limited by the signal present at analog input 1.
- 3: PID output + analog input 1/PID output is added to the speed reference present at analog input 1.