Specifications for the intended use

Specifications for the intended use

Insulating material class

B, 130 °C according to IEC 60085,

Protection class,
does not apply to shaft feedthrough

See technical data

Mounting position

See chapter "Mechanical installation"

Ventilation

Sufficient ventilation must be provided.

Insulation resistance

≥100 MΩ

Degree of pollution

2 according to EN 60204 / EN 50178

Installation altitude

Up to h ≤ 1000 m without restrictions.

The following restrictions apply to altitudes > 1000 m:

  • From 1000 m to max. 3800 m: IN reduced by 1% per 100 m
  • From 2000 m to max. 3800 m: To maintain protective separation and the air gaps and creepage distances according to EN 61800‑5‑1, an overvoltage protection device must be connected upstream to reduce the overvoltages from category III to category II.

Maximum cable length

20 m

Corrosion protection

For operation under extremely corrosive conditions, special measures must be requested from the manufacturer. These measures must be implemented immediately by the user.

Special operating conditions

The application and use of the drive must be determined and assessed on a case-by-case basis. In case of harsh ambient or operating conditions, please consult the manufacturer.