States
State machine according to CiA 402
A | Control voltage switched on, motor is not supplied with current. |
B | Control and main voltage switched on, motor is not supplied with current. |
C | Control and main voltage switched on, motor is supplied with current. |
xxx | State of the status word. |
0, 1 | Device start-up and self-test after power ON. |
13 | Fault due to drive or communication error. |
14 | Internal error processing. |
16 | Deactivation of command output inhibit "0x8100-01 – Control word". |
2, 6 | Bit 3 – 0: x110: "Switch off" command. |
3 | Bit 3 – 0: 0111: "Switch on" command. |
4 | Bit 3 – 0: 1111: "Enable operation" command. An automatic transition from "Ready to switch on" to "Operation enabled" is possible with CiA 402. |
5 | Bit 3 – 0: 0111: "Inhibit operation" command. |
11 | Bit 3 – 0: x01x: "Rapid stop" command. |
7, 8, 9, 1, 2 | Bit 3 – 0: xx0x: "Switch off voltage" command. |
15 | Bit 7: Edge 0 – 1: "Error reset" command. |
Access to the state machine
With CiA 402, the entire control system is realized using the following two objects. The two objects are mapped in the cyclical data exchange:
"0x8100-01 – Control word" | → | State machine | → | "0x8100-01 – Control word" |