Construction and technical data

The following table shows the mechanical construction and technical data of the cable:

Phoenix power cable SAC-4P-1,5-PUR/M12FST SH

Number of poles

4

Application

Power supply

Number of cable outlets

1

Shielded

Yes

Coding

T

Insulation properties

Overvoltage category

III

Degree of pollution

3

Material

Flammability class according to UL94

V0

Grip material

PP

Contact material

CuZn

Contact surface material

Ni/Au

Contact carrier material

PA

Screw fitting material

Die-cast zinc, nickel-plated

Electrical properties

Volume resistance

≤5 mΩ

Insulation resistance

≥100 MΩ

Nominal voltage VN

DC 63 V

Nominal current IN

12 A

Protective circuit

Not connected

Mechanical properties

Mating cycles

> 100

Plug connector

Connection 1 mounting position

Free cable end

Connection 2 mounting position

Straight socket, M12

Connection 2 coding type

T (power)

Cable/line

Cable length

1.5 m (3 m, 5 m, 10 m)

Cable weight

133 kg/km

UL AWM style

20233 / 10493 (80 °C/300 V)

Number of poles

4

Shielded

Yes

Cable type

PUR halogen-free black

Cable cross section

4 x 1.5 mm²

Wire diameter including insulation

2.4 mm

Outer cable diameter

9.7 mm ±0.3 mm

Outer cable jacket material

PUR

Outer cable jacket color

Black RAL9005

Conductor material

Bare copper litz wire

Core insulation material

PP

Single conductor color

Brown, white, blue, black

Insulation thickness

1.2 mm (outer cable jacket)

Total strands

4 cores, optimally twisted

Maximum conductor resistance

≤13.3 Ω/km (at 20 °C)

Insulation resistance

≥10 MΩ/km (at 20 °C)

Nominal cable voltage

AC 300 V

Test voltage

AC 1500 V (5 min.)

Smallest bending radius, fixed installation

49 mm

Smallest bending radius, flexible installation

73 mm

Maximum bending cycles

4000000

Torsional stress

± 25 °/m

Halogen free

According to DIN EN VDE 0472 Part 815

According to IEC 60754-1

Flame resistance

According to EN 60332-1-2

According to EN UL 1581 VW1

Oil resistance

According to DIN EN 60811-2-1

According to DIN EN 50363-10-2

Ambient temperature (operation)

-40 °C to +90 °C (cable, fixed installation)

-30 °C to +90 °C (cable, flexible installation)

Ambient conditions

Degree of protection

IP65

IP67

Ambient temperature (operation)

-25 °C to +85 °C (plug/socket)

Standards and regulations

Standard designation

M12 plug connector

Standards/regulations

IEC 61076-2-111

Approvals

UL Listed

Nominal voltage VN 63 V

Nominal current IN 12 A

Cross section AWG --

Cross section mm² – 16

cUL Listed

Nominal voltage VN 63 V

Nominal current IN 12 A

Cross section AWG – 16

Cross section mm² --

EAC-RoHS

 

cULus Listed

 

Classifications

ECLASS-11.0

27060311

ECLASS-12.0

27060311

ECLASS-13.0

27060327

ETIM 9.0

EC001855

UNSPSC 21.0

26121600

Compliance with environmental regulations

China RoHS

Period for designated use: unlimited=EFUP-e

No hazardous substances above the limit values