Fault 46 MOVISAFE® CS..A

Fault: 46.1 (2E01hex | 11777dec)

Description: MOVISAFE® CS..A safety option no longer responding

 

Response: Output stage inhibit

Cause

Measure

No synchronization could be performed with the safety option.

– When using a pluggable safety option, check the device assignment of the basic device and the safety option.

– When using a pluggable safety option, check the slot and installation of the safety option.

– Switch the device off and on again.

– If the fault occurs repeatedly, contact SEW‑EURODRIVE Service.

Fault: 46.2 (2E02hex | 11778dec)

Description: Invalid variant

 

Response: Output stage inhibit

Cause

Measure

Safety option variant does not match inverter type.

Use the correct safety option variant.

In a double axis of the MOVIDRIVE® modular application inverter, only safety options without an encoder interface may be used.

Use the correct safety option variant.

Fault: 46.3 (2E03hex | 11779dec)

Description: MOVISAFE® CS..A safety option no longer responding

 

Response: Output stage inhibit with self-reset

Cause

Measure

Communication between inverter and safety option interrupted.

– When using a pluggable safety option, check the installation.

– If the fault occurs repeatedly, contact SEW‑EURODRIVE Service.

Safety option has signaled a warning.

– When using a pluggable safety option, check the installation.

– If the fault occurs repeatedly, contact SEW‑EURODRIVE Service.

Fault: 46.50 (2E32hex | 11826dec)

Description: Warning

 

Response: Warning with self-reset

Cause

Measure

Safety option has signaled a warning.

Observe the warning of the safety option subcomponent. Identify the exact cause of this warning and take the appropriate measures for elimination.

Fault: 46.51 (2E33hex | 11827dec)

Description: Fault

 

Response: Emergency stop + output stage inhibit with self-reset

Cause

Measure

Safety option detected a fault.

Observe the fault code of the safety option subcomponent. Identify the exact cause of this fault message and take the appropriate measures to eliminate the fault.

Fault: 46.52 (2E34hex | 11828dec)

Description: System fault/data fault/critical fault

 

Response: Output stage inhibit with self-reset

Cause

Measure

The MOVISAFE® CS.. safety option has detected a fault.

Open the fault status of the safety option in section [Diagnostics] > [MOVISAFE® CS..]. Identify the exact cause of this fault message of highest priority and take the appropriate measures to eliminate the fault.