Fault 44 Subcomponent power section
Fault: 44.2 (2C02hex | 11266dec) Description: Overcurrent phase U | ||
---|---|---|
| Response: Remote – critical fault | |
Cause | Measure | |
The connected motor is too large. | Connect a smaller motor. | |
Acceleration too high. | Reduce the acceleration. | |
A short circuit has occurred. | – Remove the short circuit on the motor connection. – Check the motor phases. | |
There is a problem with the output filter. | – Activate the output filter during startup of the drive train. – Check assignment of output filter and inverter. | |
Output stage defective. | Contact SEW-EURODRIVE Service. |
Fault: 44.3 (2C03hex | 11267dec) Description: Overcurrent phase V | ||
---|---|---|
| Response: Remote – critical fault | |
Cause | Measure | |
The connected motor is too large. | Connect a smaller motor. | |
Acceleration too high. | Reduce the acceleration. | |
A short circuit has occurred. | – Remove the short circuit on the motor connection. – Check the motor phases. | |
There is a problem with the output filter. | – Activate the output filter during startup of the drive train. – Check assignment of output filter and inverter. | |
Output stage defective. | Contact SEW-EURODRIVE Service. |
Fault: 44.4 (2C04hex | 11268dec) Description: Overcurrent phase W | ||
---|---|---|
| Response: Remote – critical fault | |
Cause | Measure | |
The connected motor is too large. | Connect a smaller motor. | |
Acceleration too high. | Reduce the acceleration. | |
A short circuit has occurred. | – Remove the short circuit on the motor connection. – Check the motor phases. | |
There is a problem with the output filter. | – Activate the output filter during startup of the drive train. – Check assignment of output filter and inverter. | |
Output stage defective. | Contact SEW-EURODRIVE Service. |