Fault 44 Subcomponent power section

Fault: 44.2 (2C02hex | 11266dec)

Description: Overcurrent phase U

 

Response: Remote – critical fault

Cause

Measure

The connected motor is too large.

Connect a smaller motor.

Acceleration too high.

Reduce the acceleration.

A short circuit has occurred.

– Remove the short circuit on the motor connection.

– Check the motor phases.

There is a problem with the output filter.

– Activate the output filter during startup of the drive train.

– Check assignment of output filter and inverter.

Output stage defective.

Contact SEW-EURODRIVE Service.

Fault: 44.3 (2C03hex | 11267dec)

Description: Overcurrent phase V

 

Response: Remote – critical fault

Cause

Measure

The connected motor is too large.

Connect a smaller motor.

Acceleration too high.

Reduce the acceleration.

A short circuit has occurred.

– Remove the short circuit on the motor connection.

– Check the motor phases.

There is a problem with the output filter.

– Activate the output filter during startup of the drive train.

– Check assignment of output filter and inverter.

Output stage defective.

Contact SEW-EURODRIVE Service.

Fault: 44.4 (2C04hex | 11268dec)

Description: Overcurrent phase W

 

Response: Remote – critical fault

Cause

Measure

The connected motor is too large.

Connect a smaller motor.

Acceleration too high.

Reduce the acceleration.

A short circuit has occurred.

– Remove the short circuit on the motor connection.

– Check the motor phases.

There is a problem with the output filter.

– Activate the output filter during startup of the drive train.

– Check assignment of output filter and inverter.

Output stage defective.

Contact SEW-EURODRIVE Service.