Fault 37 Brake control

Fault: 37.1 (2501hex | 9473dec)

Description: Brake control 1 – switching state not consistent

 

Response: Brake control 1 – status

Cause

Measure

The switching state of the input signal "Brake control 1 – status" differs from the switching state of the brake control (DB 00/SBC).

– Check the connection and function of brake control 1.

– Check whether the selected connection is compatible with the monitoring of brake control.

– Check the connection and configuration of the input signal "Brake control 1 – status".

Fault: 37.2 (2502hex | 9474dec)

Description: Brake control 1 – switching frequency exceeded

 

Response: Brake control 1 – switching frequency

Cause

Measure

Permitted switching frequency of brake control 1 exceeded.

– Check the application.

– Check the permitted switching frequency of brake control and the limit value of monitoring.

Fault: 37.3 (2503hex | 9475dec)

Description: Brake control 2 – switching state not consistent

 

Response: Brake control 2 – status

Cause

Measure

The switching state of the input signal "Brake control 2 – status" differs from the switching state of the brake control (DB 00/SBC).

– Check the connection and function of brake control 2.

– Check whether the selected connection is compatible with the monitoring of brake control.

– Check the connection and configuration of the input signal "Brake control 2 – status".

Fault: 37.4 (2504hex | 9476dec)

Description: Brake control 2 – switching frequency exceeded

 

Response: Brake control 2 – switching frequency

Cause

Measure

Permitted switching frequency of brake control 2 exceeded.

– Check the application.

– Check the permitted switching frequency of brake control and the limit value of monitoring.