MOVI-C® CONTROLLER with CMM.. memory module in the inverter

If the data management (axis data set recovery) of the MOVI-C® CONTROLLER is used, the parameter and configuration settings of the controller are always transferred to the inverter.

The data is on the memory card of the MOVI-C® CONTROLLER. If the data management of the MOVI-C® CONTROLLER is not active, the memory source can be set in index 8431.20 (memory source) as follows:

  • 0 - Any
  • The parameter and configuration settings are written both to the internal device memory of the inverter and to the CMM.. memory module. Thus, the data is synchronized on both storage media.
  • 1 - Internal memory
  • The inverter reads or writes the parameter and configuration settings to the internal device memory of the inverter.
  • 2 - Replaceable memory module
  • The inverter reads or writes the parameter and configuration settings to the CMM.. memory module.