Deactivation
WARNING
Danger due to unexpected startup. If you deactivate the prioritized terminal control, the drive is immediately controlled by the original control source. Depending on the settings of the original control source, the drive may restart unexpectedly.
Severe or fatal injuries.
- Check the parameters and signals of the original control source before deactivating.
- Make sure that the settings of the parameters and signals of the original control source do not pose any risks.
If you reset the "Activation" signal, the prioritized terminal control is deactivated.
- The inverter no longer responds to the signals at the digital inputs of the prioritized terminal control.
- The inverter only responds to the parameters and signals of the original control source (e.g. fieldbus signals, other inverter functions, etc.).