Data flow

  • The difference of the master signal position is formed. Position differences are processed internally.
  • The "State machine" block implements the synchronization and desynchronization mechanisms, including master- or time-based transition functions, in accordance with the set config data.
  • The position difference is summed to form the internal master position.
  • A phase shift can be carried out on the fly on the master side with "XOffsetCorrection".
  • In addition, the X-offset is calculated from the curve description and forwarded to the curve evaluation.
  • The curve evaluation calculates the associated slave position.
  • This is in turn calculated against the Y-offset of the curve description.
  • An amplitude shift can be carried out on the fly on the slave side with "YOffsetCorrection".
  • The result is added to the slave reference position.
  • The "Adjust" carries out the alignment based on the absolute position calculated in this manner.