Connecting external 24 V supply voltage
Proceed as follows:
- The external 24 V voltage supply can either be connected directly to the DC 24 V connection X5 or to terminal X5_A at the MDM90A master module.
- Connect the external 24 V supply voltage as follows:
- At one side on the power supply module, on the master module or on the last axis module in the axis system
- At two sides on the power supply module or master module and on the last axis module in the axis system. Arrange the interruption point of the electronics supply for a two-sided supply so that the current load of the 2 segments is divided symmetrically. If you use 2 separate power supply units, make sure that both power supply outputs have the same reference potential.
- Select the cross section of the supply cable according to the power demand of the devices to be supplied. Observe the information in chapter Project planning.
- Note that the maximum permissible length of the 24 V supply cable is 30 m.
Additional information