X1217: AC 400 V device supply and 24 V backup voltage

The following table provides information about this connection:

Function

AC 400 V device supply and 24 V backup voltage (IN)

Connection type

S15-Power, male, connector without union nut

(current load max. 20 A, max. 16 A for UL)

Connection diagram

Assignment

Contact

Function

1

L1

Line connection, phase L1 (IN)

2

L2

Line connection, phase L2 (IN)

3

L3

Line connection, phase L3 (IN)

PE

PE

Protective earth connection

A

+24 V

DC 24 V input for backup mode (IN)

B

0V24

0V24 reference potential for backup mode (IN)

The connector cannot be aligned. You should therefore check whether angled mating connectors can be used.