Diagnostics with PROFIsafe connection
The CS..A safety option with PROFIsafe connection triggers a diagnostic alarm on the F-PLC in the data exchange between the F-PLC (fieldbus master) and the safety option (fieldbus slave) in case of a fault. Simultaneously, the associated fault code is transferred via the communication connection.
The F-PLC responds to the issued diagnostic alarm if the Diagnostic alarm assembly parameter is enabled for the safety option in the F-PLC per configuration. Depending on the fieldbus used (PROFINET), the fault code of the safety option can be evaluated in the F-PLC. A diagnostic alarm does not trigger a fault response in the F-PLC (default setting of the safety option in the F-PLC).
The safety option has PROFIsafe and assembly-specific fault codes. All fault codes of the CS..A safety option are listed in a fault table.