General information
Generally, all the connection designs listed in this documentation are permitted for safety-relevant applications, insofar as the safety conditions arising from this documentation are satisfied. This means that you must ensure without fail that the DC 24 V safety inputs are activated by a safety controller or an external safety relay, so that an independent restart is not possible.
All of the safety conditions stipulated in chapters Integrated safety technology, Safety conditions and Connection variants must be satisfied on a primary basis for the basic selection, installation, and application of the safety components such as safety relay, emergency stop switch, and the approved connection variants.
The wiring diagrams in the product manual in chapter Electrical installation are block diagrams, the only purpose of which is to show the safety sub-function(s) with the relevant components. For reasons of clarity, circuit-related measures that usually always have to be implemented are not shown in the diagram. These measures are e.g.:
- Ensuring the availability of touch guards.
- Handling overvoltages and undervoltages.
- Avoiding insulation faults.
- Detecting ground faults or short circuits in externally installed lines.
- Guaranteeing the required interference immunity against electromagnetic interference.