Brake control output

Observe the following information:

  • If the brake connection and the motor connection are combined in one power cable, the brake cable must be shielded separately. The shielding of the power cable and the brake cable must be connected to the motor and inverter over a large area.
  • SEW‑EURODRIVE recommends also using a shielded brake cable for separate brake cable routing.
  • Note the different project planning criteria to determine the length of brake cable and motor cable.
  • Connect the brakes and/or brake control units to terminal strip X10 (DB0/DB00 and GND).