Configuring digital inputs/digital outputs

For configuring the digital inputs/digital outputs, the following fields are available in the Inputs/outputs menu of the configuration for the software module.

No.

Description

[1]

List of digital inputs with drop-down lists for assigning a function and displaying the physical level.

Digital input DI 00 is permanently assigned the "output stage enable" function.

All inputs set to "Data Flexibility input" and that can be edited, can be freely assigned. All other inputs are already used according to the settings of the module configuration.

[2]

List of digital outputs with drop-down lists for assigning a function and displaying the physical level.

Digital output DB 00 is permanently assigned the "brake output" function.

[3]

Selection of a default assignment for the digital outputs.

  • Freely configurable – Configure digital outputs as required using the drop-down lists under [2].
  • If you already selected a standard assignment before, their functions will be maintained in the respective fields and the drop-down lists will be enabled to change the function.
  • Control via fieldbus – Digital outputs are assigned in such a way that they can be controlled via process data word PO 5.
  • Digital outputs as in delivery state – Reset assignment of digital outputs to delivery state. See Assignment of digital outputs.