Control functions

Parameter group

Description

Speed monitoring

Setting of the behavior of speed monitoring

Stop functions

Setting of the stop function for drives with encoder. The following settings can be made for the behavior at standstill:

  • Drive energized (brake released)
  • Drive not energized (brake applied)

The stop function is active if enable is revoked (stop with FCB 13/14), if no operating mode is selected (FCB 02), and if the stop by setpoint function is enabled.

The parameter is only effective in the following operating modes: VFC (with encoder), ELSM®, and CFC. At standstill in the other operating modes, the output stage is always inhibited and the brake is applied or the DynaStop® function is activated.

Limit switches

Settings for the limit switches:

  • HW limit switch hit response
  • SW limit switch hit response
  • Use HW limit switches DT1 also in DT2