Standard engineering access

The standard engineering access differs depending on the device design.

The following table shows the access options from an engineering PC to the various controllers:

Connection:
Via the Ethernet interface of the PC

Connection to device

Device

Ethernet connection cable RJ45/RJ45, industry standard

X80

Standard engineering interface

UHX25A

UHX45A

UHX65A

X81

UHX45A

UHX65A

LAN 3

Standard engineering interface

UHX85A

Ethernet connection cable RJ45/M12, industry standard

X4224

Standard engineering interface

M12 plug connector, 4‑pin, female, D‑coded

MFC1../FHX

The standard engineering interface is available on all controllers. It has the following IP address settings in the delivery state:

  • IP address: 192.168.10.4
  • Subnet mask: 255.255.255.0
  • Standard gateway: 192.168.10.4

Some device versions have additional engineering accesses but these differ depending on the variant.