Definition of Ma_eso and FRa_eso
The values MaEmergOff and FRaEmergOff correspond to the permitted buffer torques MP and buffer radial forces FRP of the gear units.
The MP buffer torque is defined as follows:
For service factors |
| : |
|
For service factors |
| : |
|
The buffer radial force FRP is defined as follows:

Both the buffer torque MP and the buffer radial force FRP are limited to 1000 events.
Gear unit design | fEmergOff |
|---|---|
HK., HS., HW. | 1.7 |
R..7, F..7, K..7, S..7 | 1.7 |
K..9 | 1.7 |
S..7p | Depending on the gear ratio, on request |
W10 | 1.3 |
W20/30 | 1.5 |
W..7 | 1.4 |
W..9 | Depending on the gear ratio, on request |