Definition of Ma_eso and FRa_eso

The values MaEmergOff and FRaEmergOff correspond to the permitted buffer torques MP and buffer radial forces FRP of the gear units.

The MP buffer torque is defined as follows:

For service factors

:

For service factors

:

The buffer radial force FRP is defined as follows:

Both the buffer torque MP and the buffer radial force FRP are limited to 1000 events.

Gear unit design

fEmergOff

HK., HS., HW.

1.7

R..7, F..7, K..7, S..7

1.7

K..9

1.7

S..7p

Depending on the gear ratio, on request

W10

1.3

W20/30

1.5

W..7

1.4

W..9

Depending on the gear ratio, on request