Process output words

Description

Bit

Settings

PO1

Control word

0

Output stage inhibit (the motor coasts to a stop), for brakemotors the brake is applied immediately.

0: Start

1: Stop

1

Rapid stop along the second deceleration ramp/rapid stop ramp (P2-25)

0: Rapid stop

1: Start

2

Stop along process ramp P1-03/P1-04 or PO3

0: Stop

1: Start

3 to 5

Reserved

0

6

Fault reset

Edge 0 set to 1 = fault reset

7 to 15

Reserved

0

PO2

Setpoint speed in % (default setting), freely configurable with P5-09

PO3

No function, freely configurable with P5-10

PO4

No function, freely configurable with P5-11