0x8280-01 – Setpoint operating mode
Index-Sub | Type | RW | Default | Range of values | Unit | Description |
|---|---|---|---|---|---|---|
0x8280-01* | S16 | R/W | 0 | -128 – 127 |
| Setpoint operating mode |
You can use object 0x8280-01 to set the operating mode of the motor controller. The following operating modes are supported:
Mode | Description |
|---|---|
0 | No operating mode |
1 | • You can activate "Homing mode" during ongoing operation, provided you previously set a homing method using "0x8300-02 Reference travel method". • It is only possible to switch to the "Speed profile" if the state machine is in the "Switch-on inhibited" state. |
3 | Speed profile |
4 | Reserved |
6 | Reference travel (homing) |
8 | Synchronous positioning |
10 | Torque control |
15 | Commutation detection for closed loop |