Logging function

The MOVI-C® FIELD CONTROLLER has a logging function, for example, to track the processing procedures in the event of an error. The logging function is disabled by default.

INFORMATION

To keep the write operations on the memory card low and in this way prevent a defect, the logging function should not be activated permanently.

To activate the logging function, do the following:

  1. On your engineering PC connected to the MOVI-C® FIELD CONTROLLER, open the OMH memory card content using a file explorer.
  2. Navigate to the "log" directory on the OMH memory card.
    • The "log" directory contains the LogConfig.Example.xml file.
  3. Rename the LogConfig.Example.xml file into LogConfig.xml.
  • The logging function is now active.