Fault 22 Digital motor integration 2

Subfault: 22.1

Description: Communication error

 

Response: Output stage inhibit

Cause

Measure

Communication error at interface of digital motor integration.

Check the cabling.

Subfault: 22.2

Description: Slave required

 

Response: Output stage inhibit

Cause

Measure

Device started up with a drive with digital motor integration but no drive with digital motor integration is connected.

– Check the connection of the digital motor integration.

– Perform startup again.

Subfault: 22.3

Description: Incompatible drive

 

Response: Output stage inhibit

Cause

Measure

The connected drive does not match the drive that was started up.

– Connect an appropriate drive.

– Perform startup again.

Subfault: 22.4

Description: Invalid label

 

Response: Output stage inhibit

Cause

Measure

The connected drive contains invalid data.

Replace the drive.

Subfault: 22.5

Description: Incompatible slave

 

Response: Output stage inhibit

Cause

Measure

The firmware versions of the slaves used are not compatible with one another.

Update the inverter and/or the slave.

Subfault: 22.6

Description: Overload/short circuit on the interface

 

Response: Output stage inhibit

Cause

Measure

Short circuit in the cabling of a slave of digital motor integration.

Check the cabling of the slave.

The voltage of the digital motor integration slave is too low.

Check the permitted cable length.

Subfault: 22.7

Description: High current demand of slave

 

Response: Output stage inhibit

Cause

Measure

The current consumption of the slave is too high.

Use a slave with lower current consumption.

Subfault: 22.8

Description: Parameter error

 

Response: Output stage inhibit

Cause

Measure

Error while processing data from digital motor integration slave.

Repeat the process in configuration state.

Subfault: 22.9

Description: Illegal hot plug

 

Response: Emergency stop + output stage inhibit

Cause

Measure

A slave of digital motor integration was connected while the drive was enabled.

– Activate the configuration state of the inverter, e.g. by inhibiting the output stage.

– Switch the inverter off and on again.

– Connect the slave when it is de-energized.

A slave of digital motor integration was connected while the inverter was in standby mode without switching off the encoder supply.

– Switch off encoder supply in standby mode.

– Connect the slave when it is de-energized.

Subfault: 22.10

Description: Connection type not configured correctly

 

Response: Output stage inhibit

Cause

Measure

The connection type of the connected drive cannot be determined.

Set the connection type on the drive correctly.

Subfault: 22.11

Description: Illegal subslave

 

Response: Output stage inhibit

Cause

Measure

The device cannot be operated with a subslave connected via digital motor integration.

Connect another subslave.

Subfault: 22.12

Description: Slave/subslave not accessible – fault

 

Response: Emergency stop + output stage inhibit

Cause

Measure

A slave/subslave of digital motor integration is in the Device Update Manager.

Update the firmware of the slave/subslave.

– If the fault occurs repeatedly, contact SEW‑EURODRIVE Service.

Subfault: 22.13

Description: Slave/subslave not accessible – warning

 

Response: Warning

Cause

Measure

A slave/subslave of digital motor integration is in the Device Update Manager.

Update the firmware of the slave/subslave.

– If the fault occurs repeatedly, contact SEW‑EURODRIVE Service.

Subfault: 22.20

Description: Slave – critical fault

 

Response: Output stage inhibit

Cause

Measure

A slave of digital motor integration detected a critical fault.

Observe the fault message of the subslave. Identify the exact cause of this fault message and take the appropriate measures to eliminate the fault.

Subfault: 22.21

Description: Slave – fault

 

Response: Emergency stop + output stage inhibit

Cause

Measure

A slave of digital motor integration detected a fault.

Observe the fault message of the subslave. Identify the exact cause of this fault message and take the appropriate measures to eliminate the fault.

Subfault: 22.22

Description: Slave – warning

 

Response: Warning

Cause

Measure

A slave of digital motor integration issued a warning.

Observe the warning of the subslave. Identify the exact cause of this warning and take the appropriate measures for elimination.