Fault 24 Cam switch
Subfault: 24.1 Description: Cam window limits interchanged | ||
|---|---|---|
| Response: Warning | |
Cause | Measure | |
Left cam window limit larger than right limit. | Check cam window limits and adjust. | |
Subfault: 24.2 Description: Cam window limit outside modulo positioning range | ||
|---|---|---|
| Response: Warning | |
Cause | Measure | |
Cam window limits outside modulo positioning range. | Check cam window limits and adjust. | |
Subfault: 24.3 Description: Overlapping cam windows in track | ||
|---|---|---|
| Response: Warning | |
Cause | Measure | |
Cam window limits of a track overlap. | Adjust the cam window limits in such a way that they are flush. | |
Subfault: 24.4 Description: Modulo – minimum interpretation and modulo – maximum interpretation not plausible | ||
|---|---|---|
| Response: Warning | |
Cause | Measure | |
The value of the "Modulo – minimum interpretation" parameter is greater than the "Modulo – maximum interpretation" parameter. | Correct the parameter values. | |