Fault 20 Device monitoring

Error: 20.1 (1401hex | 5121dec)

Description: Supply voltage fault

 

Response: Remote – critical fault

Cause

Measure

Internal electronics supply voltage or externally connected DC 24 V supply voltage not within permitted voltage range.

– Check the voltage level of the external DC 24 V supply voltage and check for correct connection.

– Acknowledge the fault.

– If the fault occurs repeatedly, contact SEW‑EURODRIVE Service.

24 V power supply unit overloaded.

Check the project planning for the power demand.

Error: 20.8 (1408hex | 5128dec)

Description: Fan – warning

 

Response: Remote – warning with self-reset

Cause

Measure

Fan function impaired.

– Check fan for dirt.

– If the warning occurs repeatedly, contact SEW‑EURODRIVE Service.

Error: 20.9 (1409hex | 5129dec)

Description: Fan – fault

 

Response: Remote – standard fault

Cause

Measure

The fan is defective.

Contact SEW‑EURODRIVE Service.