Data flow
- The difference of the master signal position is formed. Position differences are processed internally.
- The "State machine" block implements the synchronization and desynchronization mechanisms, including master- or time-based transition functions, in accordance with the set config data.
- A phase shift can be carried out on the fly on the master side with "XOffsetCorrection".
- The position difference is scaled with a numerator/denominator. The remainder follows without losses.
- An amplitude shift can be carried out on the fly on the slave side with "YOffsetCorrection".
- The scaled position differences are again summed to form an absolute position for the slave.
- The "Adjust" carries out the alignment based on the absolute position calculated in this manner.
- The two values "Reference position master" and "Reference position slave" define the last synchronous point.