IN

Changes to these variables are applied immediately.

The dynamic parameters are scaled in user units.

Variable name

Description

xActivate

Data type – BOOL

  • TRUE – Activate
  • FALSE – Stop

If xActivate is set to "FALSE", the operating mode stops at the last setpoint position, and speed and acceleration go to zero.

xStart

Data type – BOOL

  • TRUE – Start function
  • FALSE – Stop function

xLimitSwitchNegative

Data type – BOOL

Input for the negative hardware limit switch. For reference travel types that evaluate this input, the user will need to connect the input in an appropriate manner.

  • TRUE – Negative hardware limit switch is approached
  • FALSE – Negative hardware limit switch is not approached

xLimitSwitchPositive

Data type – BOOL

Input for the positive hardware limit switch. For reference travel types that evaluate this input, the user will need to connect the input in an appropriate manner.

  • TRUE – Positive hardware limit switch is approached
  • FALSE – Positive hardware limit switch is not approached

xReferenceCam

Data type – BOOL

Input of the reference cam

For reference travel types that evaluate this input, the user will need to connect the input in an appropriate manner.

  • TRUE – Approach limit switch
  • FALSE – Do not approach limit switch