Operation

To operate the HFFS machine, perform the following steps in the MOVIKIT® fieldbus monitor. See also MOVIKIT® fieldbus monitor and the cycle diagram as well as the descriptions of the process sequence and signal states in the next chapters.

  1. Enable all axes.
  2. Select the following reference positions:
    • Master: 50 (0.5 cycle)
    • InFeed: 0 (0.00 mm)
    • RotaryKnife: 0 (0.00 °)
    • OutFeed: 0 (0.00 mm)
  3. Reference all axes.
  4. Select the operating modes.
    • Master: 200
    • InFeed: 1400
    • RotaryKnife 1400
    • OutFeed: 1000
  5. Specify the dynamic values for the "master" axis.
    • Speed: 30 cycles/min
    • Acceleration: 30 cycles/(min*s)
    • Deceleration: 30 cycles/(min*s)
  6. Specify the dynamic values for the "RotaryKnife" axis.
    • Speed: 180 °/s
    • Acceleration: 180 °/s^2
    • Deceleration: 180 °/s^2
  7. Specify the application-specific parameters for the "InFeed" axis.
    • Product length: 15000 (150.00 mm)
  8. Specify the application-specific parameters for the "RotaryKnife" axis.
    • Number of tools: 1
    • Knife diameter: 3000 (30.00 mm)
    • Product length: 15000 (150.00 mm)
    • Synchronous angle: 4500 (45.00 °)
    • Sync correction: 0 (0.000%)
  9. Start the automatic operating modes of the "InFeed" and "RotaryKnife" axes, and start the "gearing" operating mode of the "OutFeed" axis.
  10. Wait for the "in position" feedback of the "InFeed", "RotaryKnife" and "OutFeed" axes.
  11. Start the "master" axis.