Config (ST_Config_TensionSpeed)

Variable name

Description

lrTaperTensionReduction

Data type – LREAL

Winding characteristics – reduction of tension at maximum diameter in %

lrTaperWindingConstant

Data type – LREAL

Winding characteristics – gradient of tension reduction in the range of 0.8 (steep) – 1.5 (flat)

uiTolerance

Data type – UINT

Tolerance window in % in which the lrActualTension output signal must be located if closed-loop tension control is active so that the xSetpointReached output signal can be set to "TRUE".

Tolerance window = lrSetpointTension ± uiTolerance

uiInRangeTime

Data type – UINT

Duration in ms for how long the lrActualTension output signal must be in the tolerance window if closed-loop tension control is active so that the xSetpointReached output signal is set to "TRUE".

uiOutRangeTime

Data type – UINT

Duration in ms for how long the lrActualTension output signal must be outside tolerance window if closed-loop tension control is active so that the xSetpointReached output signal is set to "FALSE".

stPID

Data type – ST_Config_PID

Configuration – PID (ST_Config_PID)

stGeneral

Data type – ST_Config_General

Configuration – general (ST_Config_General)